<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>sys</ParameterFamily>
<LongName>
sys_pressure_thresh
</LongName>
<Name>
spt
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800_Auto</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
<ListItem><TextApplies>ThermoFlex</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This is the minimum system pressure in PSI that will reliably run the
pneumatic actuators in the CTP machine.  If the system pressure falls
below this value plate loading and imaging can not proceed.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>70 PSI</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 100 PSI</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
This parameter became neccessary when Trendsetters were shipped with new
"Trendsetter Engine Electronics" (TEE) boards.  These boards replaced
two previous boards (LUE and TIF boards) which read a single digitial value
from the pressure system regulator to determine good pressure.  The TEE
board in newer Trendsetters contains a pressure transducer which reads
the system pressure as an analog value.  The sys_pressure_thresh parameter
is used to compare for acceptable system pressure.
</text></DescriptionText>
<DescriptionText><text>
This parameter will appear if older Trendsetters (contaning LUE and TIF
boards) have their firmware upgraded but will have no function or effect
in those machines.
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/cal_pressure.xml</LinkAddress><LinkTitle>Command: cal pressure</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:44 2008 PST
</Updated>
<Links>
</Links>
</Parameter>